1, Test result
Test items Test evaluation Remarks
Electric eye chart test Pass
DOM testing Pass
Power consumption test Pass
BER test of error rate tester Pass Using 10G-Bert bit error meter to stream for 12 hours
Compatibility testing Pass Switch H3C-S6520
2, Test records
a, Eye chart performance testing
Test environment:
At room temperature, the error code analyzer sends a code (rate 10.3125G, code type prbs31), and tests the module’s optical/electrical eye diagram on an oscilloscope;
Optical eye pattern waveform:

Electric eye diagram waveform (R+ R -)

Eye chart performance test result: PASS
b, DDM testing
Test environment: At room temperature (18-25 ℃), power on the sample module in the fixture and work in the self loop for half an hour to stabilize the temperature before testing;

c, Power consumption testing
testing environment: Operate the module at an ambient temperature of 0/25/70 ℃; After the temperature stabilizes, record the current and voltage values and calculate the power consumption.

d, Data stream error testing
Testing environment: Instrument is Stelight ® 32G-Bert, port 3 in the figure below shows the tested 10G LR module.

Starting time of flow starting: PM 16:30 on April 28th, 22

On the 22nd/4th/29th, at AM: 09:00, the flow query lasted for about 16 hours and no BER error was found.

Data signal error test result: PASS
f, Compatibility testing (Switch H3C-S6520)

Switch software and hardware version information:
Port status:
DDM Information:

Switch compatibility test result: PASS